File-Level Event Point Modes
In file-level Event Points, does APPX report reliably on the 'real' mode of 
the I/O?

For example, if we're adding a record in an INPUT process, and a file-level 
event point fires incrementing a value in a parent table, how does the  file-
level Event Point for the event report set flags indicating what's going on?

When the event triggering the firing of the File EP's is an ILF statement, 
then INTERACTIVE PHASE and MODE both are inferred from the ILF statement 
itself:

   WRITE - Add
   REWRITE - Change
   DELETE - Delete

This is true even if the ILF statement is itself part of a File EP.

Another interesting point:  In a File's POST READ event point, if it fired off
because of an ILF statement, then ...

 - INQUIRE is inferred if the read operation was without a hold on the record
 - CHANGE  is inferred if the read operation was with a hold on the record.

This then results in both INTERACTIVE PHASE and MODE being set accordingly.

1) The MODE and INTERACTIVE PHASE are not what they are in the Input process.
   You will not see DATA SCROLL for instance.

2) Multilevel process families.  For example, if you add an order in Order
   Entry:

You add some header info, then lineitem info, then to the header and down to 
charge/allowance items, then back to the header and down to order comments, 
then back to the header to complete the order.

      You will get several file level event points fired.  When you go from
      the header down to the lineitems while adding the order, APPX will write
      the order header PCF and fire the event points with a MODE=ADD, but the 
      order is not done yet.

      It will then re-trigger the file event points several more times in 
      MODE=CHANGE as it resaves the PCF during the remaining entry of the 
      order including the exit from the final frame of the order header to 
      complete the order.

      So, if you want to do something when the order is completed, you need   
      some way to detect a completed order other than MODE=ADD in the file 
      level event point.

      Also, File Event Points are fairly isolated from the trigger process 
      that fires them.  You can't set a workfield in your input process and 
      check it in the file event point.  Only the PCF record is shared.
[Append to This Answer]
2004-Jan-02 10:43am
Previous: (Answer) How does the pivot year logic work?
Next: (Answer) Can a button with a picture be resized using APPX software alone?
This document is: http://board.appx.com/cgi-bin/fom.cgi?file=246
[Search] [Appearance]
This is a Faq-O-Matic 2.719.
Copyright 2003 by APPX Software, Inc. All rights reserved.